Скачать с ютуб ECM Blower Diagnosis on a Carrier Infinity System (HVAC Variable Speed Blower Diagnosis) в хорошем качестве

ECM Blower Diagnosis on a Carrier Infinity System (HVAC Variable Speed Blower Diagnosis) 5 лет назад


Если кнопки скачивания не загрузились НАЖМИТЕ ЗДЕСЬ или обновите страницу
Если возникают проблемы со скачиванием, пожалуйста напишите в поддержку по адресу внизу страницы.
Спасибо за использование сервиса savevideohd.ru



ECM Blower Diagnosis on a Carrier Infinity System (HVAC Variable Speed Blower Diagnosis)

Bryan woke up to an error on his Carrier Infinity system, so he tries to find out what went wrong and how to fix it. This video shows Bryan's ECM blower diagnosis and covers how to do an HVAC variable speed motor diagnosis with the Genteq TecInspect. The errors were Error 41-Blower Motor Fault and Error 44-Cannot Communicate With Blower. The communications light was on, but the status light was blinking at the control board. Bryan started by restarting the power to see if anything changed. While the power was off, Bryan checked the plugs and blower condition. The plugs seemed to be in good condition, and the blower didn't appear to be stuck. After forcing the time delay off using the thermostat, we still saw that the blower wasn't communicating with the board. The static pressure was a little bit higher than normal because Bryan made the unit run at maximum airflow for a video, but that shouldn't have been a problem that would have led to the current situation (the static pressure stayed within the normal operation range). Bryan's main suspicion was that the higher RPM was what led to a failure in the motor module, which made the motor unable to communicate with the blower. We removed the blower to separate the motor from the module. Bryan confirmed that the motor would run shortly upon startup, but it would fail to communicate and would stop running. There didn't appear to be any bearing or winding abnormalities when we took it apart. We swapped out the module at Kalos; it had the same horsepower but didn't have the "3.0" label. On systems with VFDs, be sure to leave it disconnected from high voltage for about 5 minutes for safety reasons. Having read the windings against each other, we determined that they had roughly the same resistance (which is normal for three-phase motors). After checking them all to ground, we determined that there was no significant resistance. The new motor module was installed, and the error code went away on the board. There were no error codes at the thermostat, and the blower only drew 2.1 amps. The static pressure was at 0.4"wc, and all was well. Carrier: https://www.carrier.com/carrier/en/us/ Read all the tech tips, take the quizzes, and find our handy calculators at https://www.hvacrschool.com/

Comments